The device operates on a DC9V power supply using a 6F22 battery. It has a low static current of ≤10µA and an alarm current of ≤30mA. The alarm output includes both sound and flashing indicators, with a red LED used for alarm indication. The sound pressure level (SPL) is greater than 80dB at a distance of 3 meters. It functions within a temperature range of -10°C to +50°C and can withstand humidity levels up to 95% RH without condensation. The alarm triggers at a temperature of 57°C. The device can be mounted up to 12 meters high and covers a detection area of up to 60 square meters at a height of 6 meters. It is white in color and has a compact size of Φ107 mm in diameter and 35 mm in height. It adheres to the GB 20517-2006 standard.
Table Format
| Specification | Details |
|---|---|
| Operating Voltage | DC9V (1x6F22 battery) |
| Static Current | ≤10µA |
| Alarm Current | ≤30mA |
| Alarm Output | Sound + Flash |
| Alarm Indication | Red LED |
| SPL | >80dB at 3 meters |
| Operating Temperature | -10°C to +50°C |
| Humidity | ≤95% RH (No condensation) |
| Alarm Temperature | 57°C |
| Maximum Mounted Height | 12 meters |
| Detection Area | 60 square meters (at 6m height) |
| Color | White |
| Size | Φ107 x 35 mm |
| Standard | GB 20517-2006 |


















Reviews