2 x 12V / 7Ah (NW-8300-8) Conventional Fire Control Panel

  • Model: NW-8300-8
  • Mains voltage: 110-240 AC ± 10%, 50Hz
  • Battery voltage: 2 x 12V / 7Ah
  • System voltage: 29V DC Nominal
SKU: ARP1315

Original price was: SAR 822.00.Current price is: SAR 685.00.

  • Model: NW-8300-8
  • Mains voltage: 110-240 AC ± 10%, 50Hz
  • Battery voltage: 2 x 12V / 7Ah
  • System voltage: 29V DC Nominal
19 People watching this product now!
[product_acf_field]

Payment Methods:

Description

The NW-8300-8 Conventional Fire Control Panel is engineered for effective fire detection and alarm management, providing robust features for various applications. It operates on a mains voltage of 110-240 AC (±10%) at 50Hz and is powered by two 12V 7Ah batteries, ensuring reliable operation even during power outages. The panel maintains a nominal system voltage of 29V DC with a maximum ripple of 200mV, ensuring stable performance. Designed to handle a maximum zone capacity of 20 devices per zone, it operates at a zone voltage of 21V DC (with a range of 20-22.5V). The sounder activation delay can be set from 0 to 18 minutes in 30-second increments, offering flexibility for alarm response. The panel includes 4.7kΩ resistors for both zone and sounder end-of-line devices, enhancing circuit integrity. Safety features include short circuit protection for zones (set at 100mA) and the charger (for batteries below 20V), with a supply voltage maintained at 27V (±1V).

Feature Specification
Model NW-8300-8
Mains Voltage 110-240 AC ± 10%, 50Hz
Battery Voltage 2 x 12V / 7Ah
System Voltage 29V DC Nominal
System Voltage Ripple 200mV MAX
Charger Size Up to 7Ah in 24 hours
Zone Voltage 21V DC Nominal (20-22.5V)
Maximum Zone Capacity 20 devices per zone
Sounder Activation Delay 0-18 Minutes (30s increments)
Zone End of Line Device 4.7kΩ Resistor
Sounder End of Line Device 4.7kΩ Resistor
Zone Short Circuit Protection 100mA
Charger Short Circuit Protection Batteries Less Than 20V
Supply Voltage 27V ± 1V

Specification

Overview

Processor

Display

RAM

Storage

Video Card

Connectivity

Features

Battery

General

Description

The NW-8300-8 Conventional Fire Control Panel is engineered for effective fire detection and alarm management, providing robust features for various applications. It operates on a mains voltage of 110-240 AC (±10%) at 50Hz and is powered by two 12V 7Ah batteries, ensuring reliable operation even during power outages. The panel maintains a nominal system voltage of 29V DC with a maximum ripple of 200mV, ensuring stable performance. Designed to handle a maximum zone capacity of 20 devices per zone, it operates at a zone voltage of 21V DC (with a range of 20-22.5V). The sounder activation delay can be set from 0 to 18 minutes in 30-second increments, offering flexibility for alarm response. The panel includes 4.7kΩ resistors for both zone and sounder end-of-line devices, enhancing circuit integrity. Safety features include short circuit protection for zones (set at 100mA) and the charger (for batteries below 20V), with a supply voltage maintained at 27V (±1V).

Feature Specification
Model NW-8300-8
Mains Voltage 110-240 AC ± 10%, 50Hz
Battery Voltage 2 x 12V / 7Ah
System Voltage 29V DC Nominal
System Voltage Ripple 200mV MAX
Charger Size Up to 7Ah in 24 hours
Zone Voltage 21V DC Nominal (20-22.5V)
Maximum Zone Capacity 20 devices per zone
Sounder Activation Delay 0-18 Minutes (30s increments)
Zone End of Line Device 4.7kΩ Resistor
Sounder End of Line Device 4.7kΩ Resistor
Zone Short Circuit Protection 100mA
Charger Short Circuit Protection Batteries Less Than 20V
Supply Voltage 27V ± 1V
  • Model: NW-8300-8
  • Mains voltage: 110-240 AC ± 10%, 50Hz
  • Battery voltage: 2 x 12V / 7Ah
  • System voltage: 29V DC Nominal
SKU: ARP1315

Description

The NW-8300-8 Conventional Fire Control Panel is engineered for effective fire detection and alarm management, providing robust features for various applications. It operates on a mains voltage of 110-240 AC (±10%) at 50Hz and is powered by two 12V 7Ah batteries, ensuring reliable operation even during power outages. The panel maintains a nominal system voltage of 29V DC with a maximum ripple of 200mV, ensuring stable performance. Designed to handle a maximum zone capacity of 20 devices per zone, it operates at a zone voltage of 21V DC (with a range of 20-22.5V). The sounder activation delay can be set from 0 to 18 minutes in 30-second increments, offering flexibility for alarm response. The panel includes 4.7kΩ resistors for both zone and sounder end-of-line devices, enhancing circuit integrity. Safety features include short circuit protection for zones (set at 100mA) and the charger (for batteries below 20V), with a supply voltage maintained at 27V (±1V).

Feature Specification
Model NW-8300-8
Mains Voltage 110-240 AC ± 10%, 50Hz
Battery Voltage 2 x 12V / 7Ah
System Voltage 29V DC Nominal
System Voltage Ripple 200mV MAX
Charger Size Up to 7Ah in 24 hours
Zone Voltage 21V DC Nominal (20-22.5V)
Maximum Zone Capacity 20 devices per zone
Sounder Activation Delay 0-18 Minutes (30s increments)
Zone End of Line Device 4.7kΩ Resistor
Sounder End of Line Device 4.7kΩ Resistor
Zone Short Circuit Protection 100mA
Charger Short Circuit Protection Batteries Less Than 20V
Supply Voltage 27V ± 1V