LS-868-11WW-SYGL-A - Combined Detector Original price was: SAR 133.40.Current price is: SAR 116.00.
Back to products
Single Beam Motion Detector - LS-808-1 Original price was: SAR 23.00.Current price is: SAR 20.00.

Arizon Launch Offer

Arizon Parts: Shop Now and Enjoy Free Delivery

DELIVERY15

Combined Smoke and Heat Detector – LS-869-37

  • Working Voltage: AC110 – 245V
  • Power Consumption: ≤2W
  • Detecting Gas Type: CH4, CO
  • Alarm Concentration:
    • CH4: 10% LEL
    • CO: 260 PPM
    • Temperature: ≥ +70°C
SKU: ARP1271

Original price was: SAR 143.75.Current price is: SAR 125.00.

  • Working Voltage: AC110 – 245V
  • Power Consumption: ≤2W
  • Detecting Gas Type: CH4, CO
  • Alarm Concentration:
    • CH4: 10% LEL
    • CO: 260 PPM
    • Temperature: ≥ +70°C
18 People watching this product now!
[product_acf_field]

Payment Methods:

Description

The gas detector operates with a voltage range of AC110 – 245V and has a power consumption of ≤2W. It is designed to detect CH4 (Methane) and CO (Carbon Monoxide) gases. The alarm triggers at CH4 concentrations of 10% LEL and CO concentrations of 260 PPM, as well as at temperatures ≥ +70°C. The response time is within 15 seconds. This detector does not have explosion-proof features and links to a solenoid valve or manipulator. It features red, green, and yellow LED indicators, with the alarm indication being a constant red light and an active buzzer with a sound pressure level greater than 90dB at 1 meter. The device operates in environments with temperatures ranging from -10°C to +55°C, humidity up to 95% RH (no condensation), and atmospheric pressure between 86 kPa and 106 kPa. It is wall-mounted and should be installed within 1.5 meters of the air source. The device complies with standard GB 15322.2-2019.

Table Format

Specification Details
Working Voltage AC110 – 245V
Power Consumption ≤2W
Detecting Gas Type CH4, CO
Alarm Concentration CH4: 10% LEL, CO: 260 PPM, Temp: ≥ +70°C
Response Time 15 seconds
Explosion-Proof None
Linkage Way Solenoid valve or manipulator
LED Indicator Red, green, and yellow
Alarm Indication Red light on, buzzer action
Alarm Sound Pressure >90dB (1m straight ahead)
Operating Temperature -10°C ~ +55°C
Operating Humidity ≤95% RH (No condensation)
Atmospheric Pressure 86 kPa ~ 106 kPa
Size 99 x 99 x 36 mm
Installation Wall-mounted, within 1.5 m of air source
Standard GB 15322.2-2019

Specification

Overview

Processor

Display

RAM

Storage

Video Card

Connectivity

Features

Battery

General

Description

The gas detector operates with a voltage range of AC110 – 245V and has a power consumption of ≤2W. It is designed to detect CH4 (Methane) and CO (Carbon Monoxide) gases. The alarm triggers at CH4 concentrations of 10% LEL and CO concentrations of 260 PPM, as well as at temperatures ≥ +70°C. The response time is within 15 seconds. This detector does not have explosion-proof features and links to a solenoid valve or manipulator. It features red, green, and yellow LED indicators, with the alarm indication being a constant red light and an active buzzer with a sound pressure level greater than 90dB at 1 meter. The device operates in environments with temperatures ranging from -10°C to +55°C, humidity up to 95% RH (no condensation), and atmospheric pressure between 86 kPa and 106 kPa. It is wall-mounted and should be installed within 1.5 meters of the air source. The device complies with standard GB 15322.2-2019.

Table Format

Specification Details
Working Voltage AC110 – 245V
Power Consumption ≤2W
Detecting Gas Type CH4, CO
Alarm Concentration CH4: 10% LEL, CO: 260 PPM, Temp: ≥ +70°C
Response Time 15 seconds
Explosion-Proof None
Linkage Way Solenoid valve or manipulator
LED Indicator Red, green, and yellow
Alarm Indication Red light on, buzzer action
Alarm Sound Pressure >90dB (1m straight ahead)
Operating Temperature -10°C ~ +55°C
Operating Humidity ≤95% RH (No condensation)
Atmospheric Pressure 86 kPa ~ 106 kPa
Size 99 x 99 x 36 mm
Installation Wall-mounted, within 1.5 m of air source
Standard GB 15322.2-2019
  • Working Voltage: AC110 – 245V
  • Power Consumption: ≤2W
  • Detecting Gas Type: CH4, CO
  • Alarm Concentration:
    • CH4: 10% LEL
    • CO: 260 PPM
    • Temperature: ≥ +70°C
SKU: ARP1271

Description

The gas detector operates with a voltage range of AC110 – 245V and has a power consumption of ≤2W. It is designed to detect CH4 (Methane) and CO (Carbon Monoxide) gases. The alarm triggers at CH4 concentrations of 10% LEL and CO concentrations of 260 PPM, as well as at temperatures ≥ +70°C. The response time is within 15 seconds. This detector does not have explosion-proof features and links to a solenoid valve or manipulator. It features red, green, and yellow LED indicators, with the alarm indication being a constant red light and an active buzzer with a sound pressure level greater than 90dB at 1 meter. The device operates in environments with temperatures ranging from -10°C to +55°C, humidity up to 95% RH (no condensation), and atmospheric pressure between 86 kPa and 106 kPa. It is wall-mounted and should be installed within 1.5 meters of the air source. The device complies with standard GB 15322.2-2019.

Table Format

Specification Details
Working Voltage AC110 – 245V
Power Consumption ≤2W
Detecting Gas Type CH4, CO
Alarm Concentration CH4: 10% LEL, CO: 260 PPM, Temp: ≥ +70°C
Response Time 15 seconds
Explosion-Proof None
Linkage Way Solenoid valve or manipulator
LED Indicator Red, green, and yellow
Alarm Indication Red light on, buzzer action
Alarm Sound Pressure >90dB (1m straight ahead)
Operating Temperature -10°C ~ +55°C
Operating Humidity ≤95% RH (No condensation)
Atmospheric Pressure 86 kPa ~ 106 kPa
Size 99 x 99 x 36 mm
Installation Wall-mounted, within 1.5 m of air source
Standard GB 15322.2-2019

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Combined Smoke and Heat Detector – LS-869-37”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5